Choose Lonnmeter for accurate and intelligent measurement!

Ultrasonic Density Meter

Short Description:

The non-nuclear density meter is appliable to real-time density measurement in all kinds of slurries. It infers the speed of sound by measuring the transmission time of sound wave from the signal source to the signal receiver. This measurement method is not affected by the conductivity, color and transparency of the liquid, ensuring extremely high reliability. Users can achieve a measurement accuracy of 0.05%~0.1%. The multi-functional ultrasonic concentration meter is able to measure Brix, solid content, dry matter or suspension. Its mechanical performances will not degrade with time for no moving parts.

Specifications


  • Power Supply: DC 24V / AC 220V
  • Density Accuracy : ±0.0005 g/cm³; ±0.005 g/cm³; ±0.001 g/cm³
  • Concentration Accuracy : 5‰, 1‰, 0.5‰
  • Temperature Accuracy: 0.01℃
  • Accuracy of Sound Wave: 0.01 m/s
  • Mode of Connection: Four Wire / Two Wire
  • Temperature of Mediums: -20 ℃ ~ +80 ℃; -20 ℃ ~ +120 ℃
  • Output Signal: 4~20mA
  • Ambient Temperature: -40 ℃ ~ +80 ℃
  • Relative Humidity: 0 ~ 98%
  • Explosive-Proof Grade: ExdllCTGb
  • Waterproof Grade: IP65
  • Max. Data Storage: 10000 Lines
  • Product Detail

    Product Tags

    Ultrasonic Slurry Density Meter

    Ultrasonic density meter is suitable for various applications like:
    1. Concentration and density monitoring
    2. Phase interface monitoring
    3. Multi-component analysis
    4. Polymerization monitoring

    Highlights

    Safe Non-nuclear Determination

     

    1. It's free of environmental restrictions for utilizing of safe and nonradiative ultrasonic technology ;

    2. Convenient and simple maintenance without nuclear source replacement.

    High Precision

     

    1. Density measurement is independent of bubbles or foams;

    2. The density sensor is insusceptible to operational pressure, abrasion and corrosion of fluids.

    Low Cost in Operation

     

    1. Low operational cost;

    2. Full-life cost is lower than inline tuning fork density meter and mass flow meter obviously.

    Ease of Use

     

    Multiple Installation Options

    1. It's reduces cost for less liable to scale and block;

    2. Multiple installation methods;

    3. It's switchable to offer readings of mass and volume concentration.

    Three installation methods are optional: insertion, flange and clamp-on type.


  • Previous:
  • Next:

  • Write your message here and send it to us